The primary and secondary coil of a transformer each have an inductance of 200 × 10-6 H. The mutual inductance (M) between the windings is 4 × 10-6 H. What percentage of the flux from one coil reaches the other?

1 Answer

+2 votes
by (40.0k points)
selected by
 
Best answer

Data: LP = LS = 2 × 10-4 H, M = 4 × 10-6 H

= 2 × 10-2

Therefore, the percentage of flux of the primary reaching the secondary is

0.02 × 100% = 2%

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.