Which process does not use air expansion for refrigeration?

(a) Claude operated process

(b) Elliott process

(c) Turbo-reciprocating process

(d) Liquefaction process

1 Answer

0 votes
by (120k points)
selected by
 
Best answer
Right choice is (b) Elliott process

To explain I would say: A novel process (elliott) does not use air expansion for refrigeration but sets up heat exchange with nitrogen coolant in strictly recuperative heat exchanger. Claude-operated process uses adiabatic expansion of 70-80% of the incoming air.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.