Which of the following technique does not require the measurement of dissolved oxygen concentrations?

(a) Dynamic gassing out method

(b) Static gassing out method

(c) Oxygen-Balance method

(d) Sulphite oxidation method

1 Answer

0 votes
by (120k points)
selected by
 
Best answer
The correct option is (d) Sulphite oxidation method

To explain: The oxygen-transfer rate is determined by the oxidation of sodium sulphite solution. This technique does not require the measurement of dissolved oxygen concentrations.

As oxygen enters solution it is immediately consumed in the oxidation of sulphite, so that the sulphite oxidation rate is equivalent to the oxygen-transfer rate. Since the dissolved oxygen concentration, is zero then the kLa may then be calculated from the equation:

kLa = OTR / C*

where OTR is the oxygen transfer rate.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.