0 votes
81 views
in Electronics by (95.6k points)
closed by
In the industrial control system, which one of the following methods is most commonly used in designing a system for meeting performance specifications?
1. The transfer function is first determined and then either a lead compensation or lag compensation is implemented
2. The transfer function is first determined and PID controllers are implemented by mathematically determining PID constants
3. PID controllers are implemented without the knowledge of the system parameters using Ziegler— Nichols method
4. PID controllers are implemented using Ziegler -- Nichols method after determining the system transfer function

1 Answer

0 votes
by (98.5k points)
selected by
 
Best answer
Correct Answer - Option 3 : PID controllers are implemented without the knowledge of the system parameters using Ziegler— Nichols method

Explanation:

In Ziegler Nicholas's method, by giving a step input, first, we obtain the response from the response curve.

∴ We need the output response curve and we don’t need any information about the system parameter.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.